A national facility management service level agreement connects day to day store operations to measurable outcomes: uptime, safety, speed, quality, and cost. An effective SLA defines scope, priorities, response and restore commitments, preventive maintenance cadence, compliance requirements, data and reporting, technology integrations, pricing controls, and governance. It must also account for modern realities like remote diagnostics, ESG reporting, refrigerant regulations, cyber risk, and severe weather resilience.
The goal of a national SLA is a consistent customer experience across markets, with predictable risk, spend, and performance. That requires precise definitions and verifiable metrics, not just “best efforts.” Use the components below to make commitments measurable and auditable across your portfolio.
SLA components and example targets:
|
Component |
What to specify |
Example 2025 target |
|---|---|---|
|
Scope & asset classes |
Include store formats, back-of-house, exterior, and covered asset lists by trade |
All HVAC, refrigeration, life-safety, electrical, plumbing, doors, signage, lighting, jan/san, exterior services |
|
Geographic coverage |
States/regions, urban vs. rural, and service deserts |
100% coverage in 50 states; rural response windows adjusted by distance bands |
|
Hours of service |
Standard hours, after-hours, blackout windows |
24/7 for life-safety and refrigeration; 7–7 local for routine |
|
Priority matrix |
Impact-based definitions and triage flow |
P1 life-safety/food safety; P2 customer-impact; P3 routine; P4 planned |
|
Response & restore |
Time to acknowledge, dispatch, arrive, and restore per priority |
P1: acknowledge 5 min, dispatch 15 min, onsite 2 hrs, restore 4 hrs; P2: onsite 4–8 hrs |
|
Uptime targets |
Asset or system availability by class |
Refrigeration 99.5%; POS and entrance/egress doors 99% |
|
Preventive maintenance |
Cadence by asset with checklists |
RTUs semiannual; filters quarterly; refrigeration quarterly; electrical PM annual |
|
Remote triage |
Use of RMS/IoT and approval to resolve remotely |
Attempt remote resolution on all P2/P3; document data trail in CMMS |
|
Compliance & safety |
Standards and laws the provider must meet |
OSHA, FDA Food Code, ASHRAE 62.1/55, NFPA 70E; EPA Section 608 for refrigerants |
|
KPIs & reporting |
Definitions, formulas, and cadence |
SLA attainment, MTTR, first-time fix rate, work order aging; weekly ops + monthly QBR |
|
Data & integrations |
CMMS of record, API, SSO, data schema, attachments |
Two-way API for status, notes, photos, quotes, invoices; SSO enabled |
|
Parts & inventory |
Availability for critical spares and lead-time rules |
Critical spares on hand; OEM lead-time mitigation plan within 48 hrs |
|
Pricing & controls |
Rate cards, trip fees, markups, NTE, quotes |
NTE at WO level; parts markup cap; quotes > NTE within 24–48 hrs |
|
Warranty & recalls |
Validation and routing rules |
Auto-route in-warranty assets; recall compliance within 24 hrs |
|
Environmental metrics |
Energy, leak rate, waste, and ESG reporting |
ENERGY STAR plan; refrigerant annual leak rate below 20% for commercial systems |
|
Cyber & privacy |
Protection for connected assets and data |
Align with NIST Cybersecurity Framework; role-based access; incident notice in 24 hrs |
|
Business continuity |
Disaster response playbooks and surge staffing |
Named incident commander; regional storm playbooks; 4-hr mobilization |
|
Governance & improvement |
RACI, escalation, reviews, and RCA |
24/7 escalation; monthly QBR, quarterly RCA on recurring failures; ISO 41001 alignment |
Clear definitions ensure life safety, food safety, and revenue critical issues receive fast action. This reduces downtime, spoilage, and customer service impact.
Predictive maintenance can reduce maintenance costs by 25 to 30 percent and reduce breakdowns by up to 75 percent. Strong SLAs define cadence and documentation requirements that support a shift from reactive work to planned care.
OSHA, FDA Food Code, ASHRAE, and NFPA requirements shape how technicians must work. Codifying them in the SLA protects customers, employees, and compliance posture.
ENERGY STAR programs typically deliver 2 to 10 percent annual savings. Refrigerant requirements under EPA Section 608 require defined leak thresholds, documentation, and repair timelines. SLAs should make these measurable.
Clear CMMS, API, SSO, and documentation standards support transparency and traceability. For connected assets, NIST alignment reduces cyber and operational risk.
ISO 41001 provides a model for leadership, planning, operations, evaluation, and improvement. It helps structure QBRs, governance, and long term planning.
Strong SLAs give facilities leaders the structure they need to manage asset health, service quality, and spend across a complex portfolio. When expectations are clear and data backed, teams make faster decisions, technicians work more efficiently, and stores operate with fewer surprises. Building this discipline into your SLA is the foundation for a safer, more resilient, and more cost effective operation.
Want to talk facilities?
Leave a comment or question below and we'll reach out!